House Medical Led Display Low Perfusion SPO2 PR finger pulse oximeter
Product Attributes
TYPE |
Home monitoring\ House Medical Device |
Category |
Pulse oximeter |
Series |
narigmed® FRO-100 |
Package |
1pcs/box, 60box/carton |
Display type |
RED LED |
Display parameter |
SPO2\PR |
SpO2 measurement range |
35%~100% Ultra wide range |
SpO2 measurement Accuracy |
±2%(70%~100%) |
PR measurement range |
25~250bpm Ultra wide range |
PR measurement Accuracy |
The greater of ±2bpm and±2% |
Anti-motion performance |
SpO2±3% PR ±4bpm |
Low perfusion performance |
SPO2 ±2%, PR ±2bpm |
Initial output time/Measurement time |
4s |
Automatic shutdown |
Power off after finger out 8s\Automatic shutdown in 8 seconds |
Comfortable |
Silicone cavity finger pad, can be worn comfortably for a long time |
Low battery indicator\Battery status |
YES |
Adjustable irradiance |
The screen brightness is adjustable |
Typical power consumption |
<30mA |
Weights |
54g(with bag without batteries) |
Dismension |
62mm*35mm*31mm |
Product Status |
Self-developed products |
Voltage - Supply |
2*1.5V AAA Batteries |
Operating Temperature |
5°C ~ 40°C 15%~95%( humidity) 50kPa~107.4kPa |
storage environment |
-20°C ~ 55°C 15%~95%( humidity) 50kPa~107.4kPa
|
Following Features
1\ High precision measurement at low perfusion
2\ anti-motion
3\ Fully silicone-covered finger pads, comfortable and non-compressive
4\ New parameter: Respiratory Rate(RR) (Tips: available at CE and NMPA).( reathing rate is also known as your breathing rate. It indicates the number of breaths you take per minute. A normal adult breathes approximately 12-20 times per minute.)
5\ Display of screen rotation function.
6\ Health Asst (health status report): There is a small eye on the screen, which flashes every eight seconds with an interval of 10 to 12 seconds. When the small eye does not flash, long press the power button to enter the health analysis prompt function, which will prompt whether hypoxia or excessive heart rate is suspected. Please wait to notify the customer of the status.
Short Description
The PI Perfusion Index (PI) is an important indicator of the perfusion capacity (i.e. the ability of the arterial blood to flow) of the body of the person being measured. Under normal circumstances, the PI ranges from >1.0 for adults, >0.7 for children, to weak perfusion when <0.3. when PI is smaller, Means the blood flow to the site being measured is lower and the blood flow is weaker. Low perfusion performance is a key indicator of oxygen measurement performance in scenarios such as critically premature infants, patients with poor circulation, deeply anaesthetised animals, people with dark skin, cold plateau environments, special test sites, etc., where blood flow is often weakly perfused and where poor oxygen measurement performance can lead to poor oxygen values at critical times.
Narigmed's blood oxygen measurement has an accuracy of ±2% of SpO2 at a weak perfusion of PI=0.025%.