Nopc-01 Silicone Wrap SPO2 Sensor With Inner Module Lemo Connector 

Short Description:

Narigmed’s blood oxygen accessories with built-in blood oxygen module are suitable for measurement in various environments, such as high altitude areas, outdoors, hospitals, homes, sports, winter, etc. It can be adapted to a variety of equipment such as ventilators, monitors, oxygen concentrators, etc. Without changing the design of the equipment itself, the blood oxygen monitoring function can be accessed through software changes, which facilitates compatible design and has low cost of modification and upgrade.


Product Detail

Product Tags

Product Attributes

TYPE

silicone wrap spo2 sensor with inner module lemo connector

Category

silicone wrap spo2 sensor\ spo2 sensor

Series

narigmed® NOPC-01

Display parameter

SPO2\PR\PI\RR

SpO2 measurement range

35%~100%

SpO2 measurement Accuracy

±2%(70%~100%)

SpO2 resolution

1%

PR measurement range

25~250bpm

PR measurement Accuracy

The greater of ±2bpm and±2%

PR resolution

1bpm

Anti-motion performance

SpO2±3%

PR ±4bpm

Low perfusion performance

SPO2 ±2%, PR ±2bpm

Can be as low as PI=0.025%  with Narigmed’s probe

perfusion Index Range

0%~20%

PI resolution

0.01%

Respiratory rate

Optional, 4-70rpm

RR resolution ratio

1rpm

Plethyamo Graphy

Bar diagram\Pulse wave

Typical power consumption

<20mA

Probe off detection

Yes

Probe failure detection

Yes

Initial output time

4s

Probe off detection\Probe failure detection

YES

Application

Adult / Paediatric / Neonatal

Power supply

5V DC

Communication method

TTL serial communication

Communication protocol

customizable

Size

2m

Application

Can be used in a monitor

Operating Temperature

0°C ~ 40°C

15%~95%( humidity)

50kPa~107.4kPa

storage environment

-20°C ~ 60°C

15%~95%( humidity)

50kPa~107.4kPa

Short Description

Narigmed's blood oxygen technology can be used in a variety of situations and on people of all skin tones, and is used by doctors to measure blood oxygen, pulse rate, respiratory rate and perfusion index. Specially optimized and improved for anti-motion and low perfusion performance. For example, under random or regular movement of 0-4Hz, 0-3cm, the accuracy of pulse oximeter saturation (SpO2) is ±3%, and the measurement accuracy of pulse rate is ±4bpm. When the hypoperfusion index is greater than or equal to 0.025%, the pulse oximetry (SpO2) accuracy is ±2%, and the pulse rate measurement accuracy is ±2bpm.

Nopc-01 Silicone Wrap SPO2 Sensor With Inner Module Lemo Connector  (3)

Following Features

1. Real-time measurement of pulse oxygen saturation (SpO2)

2. Measure pulse rate (PR) in real time

3. Real-time measurement of perfusion index (PI)

4. Measure respiratory rate (RR) in real time

5. Real-time transmission of pulse wave signals based on infrared spectrum absorption.

6. Real-time transmission of module working status, hardware status, software status and sensor status, and the host computer can issue alarms based on relevant information.

7. Three specific patient modes: adult, pediatric and neonatal mode.

8. It has the function of setting the average time of calculation parameters to obtain the response time of different calculation parameters.

9. Ability to resist motion interference and weak perfusion measurement.

10. With respiratory rate measurement.

The PI Perfusion Index (PI) is an important indicator of the perfusion capacity (i.e. the ability of the arterial blood to flow) of the body of the person being measured. Under normal circumstances, the PI ranges from >1.0 for adults, >0.7 for children, to weak perfusion when <0.3. when PI is smaller, Means the blood flow to the site being measured is lower and the blood flow is weaker. Low perfusion performance is a key indicator of oxygen measurement performance in scenarios such as critically premature infants, patients with poor circulation, deeply anaesthetised animals, people with dark skin, cold plateau environments, special test sites, etc., where blood flow is often weakly perfused and where poor oxygen measurement performance can lead to poor oxygen values at critical times. Narigmed's blood oxygen measurement has an accuracy of ±2% of SpO2 at a weak perfusion of PI=0.025%.