Nopc-01 Silicone Wrap SPO2 Sensor With Inner Module Lemo Connector
Product Attributes
TYPE |
silicone wrap spo2 sensor with inner module lemo connector |
Category |
silicone wrap spo2 sensor\ spo2 sensor |
Series |
narigmed® NOPC-01 |
Display parameter |
SPO2\PR\PI\RR |
SpO2 measurement range |
35%~100% |
SpO2 measurement Accuracy |
±2%(70%~100%) |
SpO2 resolution |
1% |
PR measurement range |
25~250bpm |
PR measurement Accuracy |
The greater of ±2bpm and±2% |
PR resolution |
1bpm |
Anti-motion performance |
SpO2±3% PR ±4bpm |
Low perfusion performance |
SPO2 ±2%, PR ±2bpm Can be as low as PI=0.025% with Narigmed’s probe |
perfusion Index Range |
0%~20% |
PI resolution |
0.01% |
Respiratory rate |
Optional, 4-70rpm |
RR resolution ratio |
1rpm |
Plethyamo Graphy |
Bar diagram\Pulse wave |
Typical power consumption |
<20mA |
Probe off detection |
Yes |
Probe failure detection |
Yes |
Initial output time |
4s |
Probe off detection\Probe failure detection |
YES |
Application |
Adult / Paediatric / Neonatal |
Power supply |
5V DC |
Communication method |
TTL serial communication |
Communication protocol |
customizable |
Size |
2m |
Application |
Can be used in a monitor |
Operating Temperature |
0°C ~ 40°C 15%~95%( humidity) 50kPa~107.4kPa |
storage environment |
-20°C ~ 60°C 15%~95%( humidity) 50kPa~107.4kPa |
Short Description
Narigmed's blood oxygen technology can be used in a variety of situations and on people of all skin tones, and is used by doctors to measure blood oxygen, pulse rate, respiratory rate and perfusion index. Specially optimized and improved for anti-motion and low perfusion performance. For example, under random or regular movement of 0-4Hz, 0-3cm, the accuracy of pulse oximeter saturation (SpO2) is ±3%, and the measurement accuracy of pulse rate is ±4bpm. When the hypoperfusion index is greater than or equal to 0.025%, the pulse oximetry (SpO2) accuracy is ±2%, and the pulse rate measurement accuracy is ±2bpm.
![Nopc-01 Silicone Wrap SPO2 Sensor With Inner Module Lemo Connector (3)](http://www.narigmed.com/uploads/9014ec35.jpg)
Following Features
1. Real-time measurement of pulse oxygen saturation (SpO2)
2. Measure pulse rate (PR) in real time
3. Real-time measurement of perfusion index (PI)
4. Measure respiratory rate (RR) in real time
5. Real-time transmission of pulse wave signals based on infrared spectrum absorption.
6. Real-time transmission of module working status, hardware status, software status and sensor status, and the host computer can issue alarms based on relevant information.
7. Three specific patient modes: adult, pediatric and neonatal mode.
8. It has the function of setting the average time of calculation parameters to obtain the response time of different calculation parameters.
9. Ability to resist motion interference and weak perfusion measurement.
10. With respiratory rate measurement.
The PI Perfusion Index (PI) is an important indicator of the perfusion capacity (i.e. the ability of the arterial blood to flow) of the body of the person being measured. Under normal circumstances, the PI ranges from >1.0 for adults, >0.7 for children, to weak perfusion when <0.3. when PI is smaller, Means the blood flow to the site being measured is lower and the blood flow is weaker. Low perfusion performance is a key indicator of oxygen measurement performance in scenarios such as critically premature infants, patients with poor circulation, deeply anaesthetised animals, people with dark skin, cold plateau environments, special test sites, etc., where blood flow is often weakly perfused and where poor oxygen measurement performance can lead to poor oxygen values at critical times. Narigmed's blood oxygen measurement has an accuracy of ±2% of SpO2 at a weak perfusion of PI=0.025%.